For halogen lights and for other purposes
Type range: TR 9600/60 - TR 9600/300
We produce also atypical transformation ratios in accordance with customer’s requirements. |
TYPE | CAPACITY [VA] | CORE [EI] | a [mm] | b [mm] | HEIGHt [mm] | x [mm] | g [mm] | f [mm] | ![]() [mm] | |
Transformer | TR9600/60 | 20 | 60/30 | 63,6 | 53,6 | 57,3 | 81,2 | 72,5 | 43,5 | 4,2 |
Transformer | TR9600/60 | 60 | 75/32,7 | 78,7 | 66,2 | 63,8 | 100 | 90 | 52,5 | 4,2 |
Transformer | TR9600/105 | 105 | 84/43,5 | 88,1 | 74,1 | 76,5 | 107,5 | 97,5 | 60 | 4,2 |
Transformer | TR9600/200 | 150 | 96/45,7 | 100,7 | 84,7 | 84,4 | 129,5 | 115 | 70 | 6,2 |
Transformer | TR9600/200 | 200 | 96/59,7 | 100,7 | 84,7 | 98,4 | 129,5 | 115 | 70 | 6,2 |
Transformer | TR9600/300 | 300 | 120/50 | 126,8 | 106,7 | 109 | 176,8 | 150,5 | 85 | 8,5 |
Transformer | TR9600/300 | 400 | 120/73 | 126,8 | 106,7 | 129 | 176,8 | 150,5 | 85 | 8,5 |
Transformer | TR9600/300 | 500 | 120/73 | 126,8 | 106,7 | 129 | 176,8 | 150,5 | 85 | 8,5 |
Transformer | TR9600/300 | 600 | 120/80 | 126,8 | 106,7 | 129 | 176,8 | 150,5 | 85 | 8,5 |
THERMAL CLASS: | E |
SHORT-CIRCUIT RESISTANCE: | RESISTANT UNDER CERTAIN CONDITIONS |
PROTECTION CLASS: | II. |
PROTECTION: | IP40 - IP64 |
THERMAL PROTECTION: | THERMAL FUSE RETURN 130°C |
ELECTRIC RESISTANCE: | 4000V/50Hz |
OUTPUTS: | NETWORK CABLE about 1.5 m LONG WITH A PLUG, OUTPUT CABLE about 0.4 m LONG, or a terminal box |
IMPREGNATION: | CASTED WITH RESIN |
AMBIENT TEMPERATURE: | +40°C |
Notes: |
|